mirror of
https://gitlab.eurecom.fr/oai/openairinterface5g.git
synced 2026-07-13 04:30:28 +00:00
CI test runner: handle SIGINT
Handle SIGINT and mark any subsequent steps as failed. Receiving SIGINT a second time will abort the script immediately (as is the case before this commit). Note that Python seems to relay the signal to the "controlled" process (e.g., Ping), which would return immediately with an error. So some steps like Ping will abort immediately, others (e.g., IdleSleep) will finish their step, and then the present logic will mark subsequent steps as failed.
This commit is contained in:
@@ -296,8 +296,16 @@ def test_in_list(test, list):
|
||||
return True
|
||||
return False
|
||||
|
||||
test_runner_abort = False
|
||||
def receive_signal(signum, frame):
|
||||
sys.exit(1)
|
||||
global test_runner_abort
|
||||
if not test_runner_abort:
|
||||
logging.warning("received signal, canceling steps")
|
||||
logging.info("send signal again to exit immediately")
|
||||
test_runner_abort = True
|
||||
else:
|
||||
logging.warning("received signal again, exiting")
|
||||
sys.exit(1)
|
||||
|
||||
def ShowTestID(ctx, desc):
|
||||
logging.info(f'\u001B[1m----------------------------------------\u001B[0m')
|
||||
@@ -488,7 +496,7 @@ elif re.match('^TesteNB$', mode, re.IGNORECASE) or re.match('^TestUE$', mode, re
|
||||
#logging.info('test will be run: ' + test)
|
||||
todo_tests.append(test)
|
||||
|
||||
signal.signal(signal.SIGUSR1, receive_signal)
|
||||
signal.signal(signal.SIGINT, receive_signal)
|
||||
|
||||
HTML.CreateHtmlTabHeader()
|
||||
|
||||
@@ -498,6 +506,8 @@ elif re.match('^TesteNB$', mode, re.IGNORECASE) or re.match('^TestUE$', mode, re
|
||||
i = 0
|
||||
for test_case_id in todo_tests:
|
||||
for test in all_tests:
|
||||
if test_runner_abort:
|
||||
task_set_succeeded = False
|
||||
id = test.get('id')
|
||||
if test_case_id != id:
|
||||
continue
|
||||
|
||||
Reference in New Issue