8107939f08 Change OAI license to CSSL v1.0 (and others)
- all RAN code, CI code, configuration files, dockerfiles, in CSSL v1.0
- all deployment code (openshift, charts, ancillary files like shell
  scripts), in MIT
- documentation in CC-BY-4.0
- exceptions might apply and are listed in NOTICE
- there is a new LICENSES folder with all licenses
- CONTRIBUTIONS.md has been updated accordingly

For automated changes based on OAI PL v1.1:

    perl -i~ -0pe 's/\/\*.*Licensed to the OpenAirInterface.*openairinterface.org\n#?/\/*\n * SPDX-License-Identifier: LicenseRef-CSSL-1.0\n/s' **/*.{c,h,cpp}
    perl -i~ -0pe 's/\/\*.*Licensed to the OpenAirInterface.*openairinterface.org\n#?/\/*\n * SPDX-License-Identifier: LicenseRef-CSSL-1.0\n/s' **/*.ts
    perl -i~ -0pe 's/<!--.*Licensed to the OpenAirInterface.*openairinterface.org\n.*-->/<!-- SPDX-License-Identifier: LicenseRef-CSSL-1.0 -->/s' **/*.xml

The rest (cmake, files with missing license, cmake) manually.
2026-03-27 16:36:37 +01:00
Jaroslava Fiedlerova
96511595f2 Reduce timing reference value for feptx_total in 40 MHz phytest
The reduction reflects improved feptx_total performance introduced in !3834.
2026-03-12 22:17:05 +01:00
Robert Schmidt
5ac381dd59 Remove dead code 2025-11-14 18:17:29 +01:00
Robert Schmidt
5d04408f5c Incorporate ru_stats_thread() stats into nrL1_stats.log
Do not pollute periodic output, and rather print those into
nrL1_stats.log. A number of them are already there anyway, so transfer
the rest. Note: ru->ifdevice.tx_fhaul is omitted, as we don't have any
IF5 split in 5G.
2025-07-01 08:54:25 +02:00
Romain Beurdouche
b1e0bfdda6 fix(CI RAN-gNB-N300-Timing-Phytest-LDPC): update reference timings
Update reference `L1 Tx processing` and `DLSCH encoding` timing in `RAN-gNB-N300-Timing-Phytest-LDPC` CI test
to reflect performance improvements.
2025-05-13 14:08:33 +00:00
francescomani
2626dbd24b further adjustment in timing test 2025-05-04 09:34:42 +02:00
francescomani
66d8cf0f13 update of timing test thresholds to reflect current values 2025-02-19 18:28:04 +01:00
Jaroslava Fiedlerova
85b163b6b9 CI: Adjust timing thresholds in timing-phytest pipeline
CI test sometimes fails because measured value is lower than allowed
threshold.
2025-01-15 14:44:39 +01:00
Bartosz Podrygajlo
793bdd86ae Adjust reference processing time for 40Mhz phytest 2024-12-05 11:32:23 +01:00
Robert Schmidt
58c2f04b40 Adapt timing-phytest stats to new LDPC decoder iterations 2024-03-05 08:04:11 +01:00
Robert Schmidt
f3bba45bfe Update some timing stats 2024-02-12 18:29:53 +01:00
Robert Schmidt
362bc481bd Remove misleading PUSCH decoding
PUSCH decoding is started multiple times in nr_ulsch_procedures() for
each ULSCH segment, and stopped once inside
phy_procedures_gNB_uespec_RX(). Not only is it not clear if that works
with the API, it also might measure more than just PUSCH decoding.

Remove the PUSCH decoding, it is misleading. Check L1 RX processing
instead.
2024-02-12 12:04:55 +01:00
Robert Schmidt
003567675c CI: phytest-timing: detect deviation from normalized values above/below
The CI would only detect a deviation from the normalized value based on
a configurable threshold, typically 1.25 (so we would tolerate a 25%
increase). However, it often happens that a timing gets shorter (e.g.,
forgot to put the timing measurements). This commit introduces a
"Deviation Threshold" (smaller than 1) to not only check that we exceed
1.0 + "Deviation Threshold" (as before), but also that are not below 1.0
- "Deviation Threshold".

In other words, assuming a maximum divergence of 25%, instead of just
checking if val > 1.25, we now also check if val < 0.75 (and flag
error).
2024-02-12 12:04:55 +01:00
Robert Schmidt
6ba8716700 Add Slot Indication to monitoring 2024-02-12 12:04:55 +01:00
Robert Schmidt
41ea99c5d1 Adapt timing thresholds after merge of !2253 2023-10-02 14:18:24 +02:00
Robert Schmidt
a1f7284ee3 Update 40 MHz 1x1 timing thresholds
These timings shifted slightly in an MR recently. Since it is only
micro-seconds, and these thresholds are much higher in the 60 MHz (1x1
and 2x2) tests, it is safe to increase.
2023-07-21 16:01:02 +02:00
Robert Schmidt
0a4e28688b Update phytest-timing test timing thresholds 2023-04-04 09:39:28 +02:00
Robert Schmidt
dff94f6b32 Update 1x1 40 and 60 MHz thresholds 2022-10-28 11:41:18 +02:00
Robert Schmidt
c9b90ed2f5 Slightly increase Sched Response default timing 2022-10-12 10:07:50 +02:00
Robert Schmidt
d5cdf6d3d8 Update timing thresholds 2022-10-04 16:40:27 +02:00
Robert Schmidt
40b33845f7 Fix thresholds, fixup html table ref name to show tabs correctly 2022-09-22 13:58:06 +02:00
Robert Schmidt
1fedf2e508 Update timing thresholds and add 60MHz case 2022-09-22 07:41:53 +02:00
Robert Schmidt
f8f20827e9 Rename DL&UL scheduling timing stats 2022-06-04 09:32:00 +02:00
Robert Schmidt
9b2fa3ca63 Increase PUSCH decoding defaults 2022-05-13 14:14:47 +02:00
Robert Schmidt
d90f9d8d6f CI: show correct Tx Processing in HTML, add processing count number 2022-02-28 14:13:01 +01:00
hardy